Factorio Fluid Wagon Pump Not Working, Aug 21, 2024 · The ru
Factorio Fluid Wagon Pump Not Working, Aug 21, 2024 · The rules of thumb for fluid wagons are as follow. There does not appear to be any visible intake valves on the fluid wagons. Dec 20, 2025 · One boiler consumes 6 units of water to produce 60 units of steam per second, one steam engine consumes 30 steam per second (3 units of water) and one offshore pump produces 1200 water per second, so each offshore pump produces enough water to supply 200 boilers: 1 2 0 0 6 = 2 0 0. . As far as I know, (from weekly "fluid wagon won't connect to pumps" threads) if the front of the train is on a curve (even slightly) then the pumps won't connect. Basically, it has to line up with the rail stops. Again, nothing happens until I delete/replace the pump. If part of your train rests on a curve you most likely won't be able to get the pumps to line up correctly. Aug 9, 2020 · From far away i can see the train is not properly aligned - pump looks almost across the center of the fluid wagon connector. Try rotating the pumps so the arrow is pointing away from the train. the pump is not connected to the fluid wagon; is the train parked in manual mode? Pumps require pixel-perfect alignment in order to connect, which is not easily done in manual mode, so be sure to set it in automatic with any stop condition to ensure reliable connection. Jul 20, 2018 · Pumps are incredibly picky about where the tank car is sitting. (Locale: English, Deutsch, 正體 中文, 简体 中文, Português Brasileiro, Русский) Aug 21, 2024 · The train pulls up to the stop. The pumps will only work if the wagon is perfectl Fluid wagons need pixel perfect alignment with pumps, so animation sprites be perfectly aligned too. The wagon next to it is closed, so the train is not parked right. If you want stuff out of the train you have to flip the pumps. As soon as the train is parked correctly that wagon will open. For ca… Mar 26, 2019 · You don't actually need train stops for pumps to work, but you need to be excatly at the right spot for pumps to work. It looks like your pumps are connected to the tank wagon, so It's not an alignment problem. 371K subscribers in the factorio community. Dec 14, 2024 · Are you trying to put oil into the train or out of the train. I recommend using alt mode by pressing alt or by clicking the button with the text alt in the lower right of the screen. , not manually driven), then i suspect it's because that wagon is on a curved track and, as a result, the pump can't connect properly with the fluid wagon. i would try moving it to a straight Aug 9, 2020 · Hello! As title says, I noticed that sometimes I am unable to make the pump working as intended and transfer fluids into the fluid wagon. And they just sit there doing nothing. Only trains on auto, only straight rails for the full length of the train (bends or diagonals mess things up), pumps directly next to the rail and make sure the pumps are pointing the right direction to fill/empty. Mar 18, 2020 · is the fluid wagon connected to the pumps/not have empty spaces inbetwee and are the pumps connected the right way/facing the right directions? you can tell if it works if the fluid wagon top sprite changes to have the pumps overhead. I cannot figure out how to get oil into fluid wagons. What am I missing here? Thanks for the help? I don't think so, because left wagon has correct pump connection. To get fluid into the fluid wagon, you need a train stationwith pumps. Because those pumps are putting fluids into the train. e. Have the train stop at a station and line your pumps up with the wagon and it should work Bonus: you can fill a fluid wagon with a max of 3 pumps. Jan 1, 2019 · Even if you align the wagon properly, if the train is not at a stop, the pump won't start. Adds sturdier (armour and vehicle grid) versions of locomotive, cargo wagon and fluid wagon. Mar 15, 2024 · Problem: When a pump is pumping fluid either to or from a train wagon, and a mod swaps it with another fluid-wagon entity, the pump will stop working. Community-run subreddit for the game Factorio made by Wube Software. Also adds unarmoured nuclear-powered locomotive. NEW: Also adds armoured draisines, which were tanks fitted with special rail chassis, able to traverse on rails. Press alt to see what direction the pumps are pushing fluid. I have tried connecting both pipes and pumps to the fluid wagon and nothing happens. pls Mar 30, 2019 · If a train station is past a curved track segment, the fluid wagons will be slightly misaligned and will not connect to the pumps. It appears the train is a… Sep 21, 2017 · The setup: I have a trainstation with 6 pumps next to a fluid wagon, 3 to pump into the wagon, 3 to pump out. I am using Krastori… The wagon next to it is closed, so the train is not parked right. I alternate via circuits which pumps should act… May 28, 2017 · Re: help: pump does not pump out fluid wagon by iceman_1212 » Sun May 28, 2017 7:48 pm assuming that you pulled up to the station on automatic mode (i. The wagon needs to be aligned with the rail grid; do this by using a train stop as a train scheduledestination, and a fueled locomotive. There are pumps for each fluid wagon, connected to the oil tank via pipes. Also make sure that the rails under the Fluid wagon are straight rails and not curved rails. ofc stops are recommended anyways but still you can do it manually without them May 7, 2017 · How to use fluid wagons? I can't seem to figure out this simple task. As I understand it, putting a curve between the station and the pumps basically means that the pumps won't connect. If I remove the pump and replace it, it pumps into the fluid wagon. Two steam engines per boiler gives us 400. 468 votes, 33 comments. Until the train leaves and makes its rounds and arrives at the station again. To fill a fluid wagon the train needs to be "On the rail grid". Pump animations are pretty precise, since the pump has to extend to a specific point on the fluid wagon to connect, so if the wagons are even a pixel off they won't work. Three of the pumps in this system will always be inactive. I think it might be related to the fact that the pump has a connect / disconnect animation and the game must handle that somehow being sure that you won't move during that anim The pump is not pumping heavy oil to the fluid wagon Screenshot: pump not working???? 0. Left wagon happens to work only because end-of-track caused left wagon to align forcefully - you can see there is no rail to the left side. Curved rails doesn't provide that pixel perfect alignment, so pumps don't work in this case. I think OP placed the fluid wagons manually without an engine, rather than using properly connected train. 15 Factorio A Screenshot of Factorio By: Luminiel I need help on this. You may back off the train a little on manual and then set it back to automatic. Correction to correction. Check to see if there are bends in the rails, the train should be straight. jrtq, ji3gwc, f4ndm, 1i0bxd, 6fcrb, 28qw3, uopva, rsxuq, pjxq, vvy3y,